Local controls
Cable remote controls (max. cable length 500 m) or wireless infrared remote controls are used to control individual units or groups of up to 8 indoor units. Additional modules allow units to be controlled from any location via apps or the Internet.
Central controls
More complex air conditioners can be controlled from a preferred central location, such as the reception or plant room. Cable lengths can be max. 2,000 m and up to 2,048 indoor units can be controlled.
Building control systems
TOSHIBA air conditioners can be interlinked with all conventional building control systems. This makes air conditioning an integral part of the central control of a building.
External controls
A range of options can be used to connect external units, issue messages or alarms, facilitate noise reduction or redundancy switching – virtually any control requirement can be met.
One control system for all units
Control via app or browser
Incorporation into existing systems
Connection of external modules
Controls at a glance
Local controls
• Cable remote controls
• Infrared remote controls
• WiFi/WLAN solutions
• Control options
Central controls
• Compliant Manager
• Smart Manager
• Touchscreen controller
• 16-line ON/OFF control
• Timer
• Web-based controller
Building control systems
• LonWorks®
• Modbus®
• BACnet®
• Coolmaster
• KNX®
External controls
• Leak detection system
• Accessory modules
• CN connector
• Redundancy box
Simple Cable Remote Control
Perfect for a hotel room.
Standard Cable Remote Control
Controls all indoor unit functions, 168 hours ON/OFF timer.
Cable Remote Control
Same as standard remote control, with 8 time events/day and 6 parameters/event.
Comfort Cable Remote Control
Same as standard, plus weekly timer, soft keys, night operation, louver lock, key lock, illuminated display.
Remote Temperature Sensor
When an exact temperature measurement is not possible via the sensor in the indoor unit or in the cable remote control.
IR Remote Control + Receiver Kits
Function range same as standard remote control, but wireless. For panel installation or external.
Combo Control
Control via mobile phone using SMS or APP.
AP-IR-WIFI
Controlling an indoor unit using a smartphone via an APP.
SmartSocket
230 V plug adapter with ON/OFF, timer and energy consumption monitoring functions.
TO-RC-WIFI
WIFI module for controlling an indoor unit using a mobile phone via an APP or Internet browser.
TO-RC-KNX®
Module for controlling an indoor unit via the KNX® Bus.
Remote On/Off + Window Contact Module
Potential-free contact for external On/Off and window contact input.
Control Board
3 analog and 3 digital inputs, 3 digital outputs for external control, alarms, and messages (for ceiling units).
Operating, Malfunction Indication, Remote On/Off Module
Operating and malfunction indication output, On/Off control as well as error message for up to 8 indoor units via a potential-free contact.
Analog Interface
Control of unit functions via 0 –10 V signals or fixed resistors.
Modbus® Interface
Control of unit functions via a Modbus register. Up to 64 interfaces are possible.
16-Line ON/OFF Control
On/Off control for up to 16 indoor units, weekly timer connection possible.
Weekly Timer
Connection via local cable FB, central FB, or TCC link network. Weekly timer/Time switch mode.
Compliant Manager
Up to 128 indoor units. Energy saving function, weekly timer can be connected, digital inputs and outputs.
Smart Manager with Energy Billing
Up to 128 indoor units. Web interface for PC control via a browser; energy monitoring and billing.
Touchscreen Controller with Energy Billing
Controls up to 512 indoor units. 12.1" multi-touchscreen, operation via PC also possible. Energy monitoring and billing. TCS net relay interface required (up to 8 units).
Web-Based Controller Master Unit
Up to 2048 indoor units. Serves as a hub for up to eight follower units. Individual or follower unit: Controls up to 256 indoor units. Can only be operated via PC. Energy monitoring and billing.
Modbus® Interface
Controls up to 64 indoor units. For integration with an on-site Modbus® system.
KNX®-16
Module for controlling up to 16 indoor units via the KNX® bus.
KNX®-64
Module for controlling up to 64 indoor units via the KNX® bus.
Coolmaster
Controls up to 64 indoor units – optional up to 128. KNX® option. Small touchscreen user interface. Control via smartphone, tablet, or PC possible.
LonWorks® Interface
Controls up to 64 indoor units. For integration with an on-site LonWorks® building control system (requires a LonWorks® network card).
Small BACnet® Interface
Controls up to 64 indoor units. For integration with an on-site BACnet® system.
Analog Interface:
Controls up to 64 indoor units. Control via 0 –10 V signals or fixed resistors. 8 analog and 2 digital inputs. 5 analog and 5 digital outputs.
BACnet® Server
Controls up to 128 indoor units. For integration with an on-site BACnet® system. TCS net relay interface required (up to 2 units).
Noise Reduction Module (RAV)
For DI & SDI size 5. Input for noise reduction (night operation). Max. capacity 0 / 50 / 75%. Compressor operating message.
Noise Reduction Cable Set (RAV)
For DI Big & SDI from size 8. Input for noise reduction (night operation), max. capacity 0 / 50 / 75%. Compressor operating message.
Redundancy Box
Switches between two indoor units (or groups) in case of a malfunction. Operating hour-dependent switching; temperature-dependent switching of two systems. Plug & Play, LAN port, monitoring via web browser possible.
Multi-Function Module
Two potential-free contact inputs; one function per module: external master ON/OFF, night operation (noise reduction), operating type priority heating/cooling.
Output Module
Three potential-free contact outputs. Operating message, malfunction notification, operating time compressor 1 and 2, output capacity in 8 stages.
CN Plug with Connection Cable
For indoor units; various input/output functions via on-site equipment.
Leak Detection & Isolation System
Leak detection with optical and acoustic alarms, conforms to EN378; additional separation of the affected indoor units possible.
Current Limiting/Load Shedding Module
Two potential-free contact inputs. External ON/OFF; capacity reduction.