Control systems
for business and industry
Comfort and efficiency, from local to centralized solutions with extensive options such as WiFi/WLAN and remote controls.
Perfect climate
Cooling and heating solutions
from TOSHIBA
High-quality air conditioners are naturally important but the control system also plays a significant part in the ease of use and efficiency of the system. Optimized settings create the perfect ambiance for every room to suit individual requirements. As well as local control options, TOSHIBA also offers a broad selection of central control systems, or the option to integrate these into the building management system.
Wired remote controls (max. cable length 500 m) or wireless infrared remote controls are used to control single units or groups of up to 8 indoor units. Additional modules allow location independent control via apps or the Internet.
More complex air conditioning systems can be controlled from any central location, such as the reception area or technical room. Cable lengths of up to 2,000 m are possible, and up to 2,048 indoor units can be controlled.
TOSHIBA air conditioning systems can be networked with all standard building management systems, making air conditioning an integral part of the central building control.
A range of options can be used to connect external units, issue messages or alarms, facilitate noise reduction or redundancy switching – virtually any control requirement can be met.
One control system for all units
Control via app or browser
Integration in existing systems
Connection of external modules
Perfect for hotel rooms.
Controls all indoor unit functions, 168 hours ON/OFF timer.
As for the standard remote control, but with 8 time events/day and 6 parameters/event.
As for the standard, plus weekly timer, soft keys, night operation, louver lock, key lock, illuminated display.
When an exact temperature measurement is not possible via the sensor in the indoor unit or in the wired remote control.
Scope of functions as for standard remote control, but wireless. For panel installation or external.
Control via mobile phone using SMS or app.
Controls an indoor unit using a smartphone and app.
230 V socket adapter with ON/OFF, timer, and energy consumption monitoring functions.
WiFi module for controlling an indoor unit using a cell phone and app or Internet browser.
Module for controlling an indoor unit via the KNX® bus.
Potential-free contact for external on/off and window contact input.
3 analog and 3 digital inputs, 3 digital outputs for external control, alarms, and messages (for ceiling units).
Operating and error signal output, on/off control, plus error message from up to 8 indoor units via potential-free contacts.
Controls unit functions via 0 – 10 V signals or fixed resistors.
Controls unit functions via a Modbus register. Up to 64 interfaces possible.
On/off control for up to 16 indoor units, weekly timer connection possible.
Connection via local wired remote control, central remote control, or TCC link network. Weekly timer/time switch mode.
Up to 128 indoor units. Energy-saving function, weekly timer can be connected, digital inputs and outputs.
Up to 128 indoor units. Web interface for PC control via a browser; energy monitoring and billing.
Controls up to 512 indoor units. 12.1" multi-touchscreen, operation via PC also possible. Energy monitoring and billing. TCS Net Relay interface required (up to 8 units).
Up to 2,048 indoor units. Serves as a hub for up to eight follower units. Single or follower unit: controls up to 256 indoor units. Operation via PC; energy monitoring and billing.
Controls up to 64 indoor units. For integration with a locally provided Modbus® system.
Module for controlling up to 16 indoor units via the KNX® bus.
Module for controlling up to 64 indoor units via the KNX® bus.
Control of up to 64 indoor units – optionally up to 128. KNX® option. Small touchscreen user interface. Control via smartphone, tablet, or PC possible.
Controls up to 64 indoor units. Control via 0 – 10 V signals or fixed resistors. 8 analog and 2 digital inputs. 5 analog and 5 digital outputs.
Controls up to 64 indoor units. For integration with a locally provided BACnet® system.
Controls up to 64 indoor units. For integration with a locally provided LonWorks® building management system (requires a LonWorks® network card).
Controls up to 128 indoor units. For integration with a locally provided BACnet® system. TCS Net Relay interface required (up to 2 units).
For DI and SDI size 5. Input for noise reduction (night operation). Max. capacity 0 / 50 / 75% Compressor operating signal.
For DI Big and SDI from size 8. Input for noise reduction (night operation), max. capacity 0 / 50 / 75%. Compressor operating signal.
Switches between two indoor units (or groups) in the event of a fault. Switchover dependent on operating hours; temperature-dependent switching on of the second system. Plug & Play, LAN port, monitoring via web browser possible.
Two potential-free contact inputs; one function per module: external master ON/OFF, night operation (noise reduction), operating mode priority heating / cooling.
Three potential-free contact outputs. Operating signal, error signal, operating time compressor 1 and 2, output capacity in 8 stages.
For indoor units; various input/output functions via locally provided equipment.
Leak detection with visual and audible alarms, conforms to EN378; additional separation of the affected indoor unit possible.
Two potential-free contact inputs. External ON/OFF; capacity reduction.
We offer a wide range of control options. The design and planning of the perfect control system is totally individual.
Our specialist partners are experts in this field. They will be happy to help you to find the best configuration for your control system. Simply use our specialist partner search to find your nearest expert.
Find a specialist partner near you
Consulting
Cooling and heating solutions from TOSHIBA